5 resultados para Achilles Tendon

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the wrist extensors’ musculotendon patterns were investigated during a manual task believed to elicit LE symptoms in susceptible subjects. A 42-year-old right-handed male, with no history of LE, performed a repetitive movement involving pushing and turning a spring-loaded mechanism. Motion capture data were acquired for the upper limb and an inverse kinematic and dynamic analysis was subsequently carried out. Results illustrated the presence of eccentric contractions sustained by the extensor carpi radialis longus (ECRL), together with an almost constant level of tendon strain of both extensor carpi radialis brevis (ECRB) and extensor digitorum communis lateral (EDCL) branch. It is believed that these factors may partly contribute to the onset of LE as they are both responsible for the creation of microtears at the tendons’ origins. The methodology of this study can be used to explore muscle actions during movements that might cause or exacerbate LE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Manipulation of an object by a multi-fingered robot hand requires task planning which involves computation of joint space vectors and fingertip forces. To implement a task as fast as possible, computations have to be carried out in minimum time. The state of the art in manipulation by multi-fingered robot hand designs has shown the possible use of remotely driven finger joints. Such remotely driven hands require computation of tendon displacement for evaluating joint space vectors before signals are sent to actuators. Alternatively, a direct drive hand is a mechanical hand in which the shafts of articulated joints are directly coupled to the rotors of motors with high output torques. This article has been divided into two main sections. The first section presents a brief view of manipulation using a direct drive approach. Meanwhile, the other section presents ongoing research which is being carried out to design a four-finger articulated hand in the Department of Cybernetics at the University of Reading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on a distributed moisture detection scheme which uses a cable design based on waterswellable hydrogel polymers. The cable modulates the loss characteristic of light guided within a multi-mode optical fibre in response to relative water potentials in the surrounding environment. Interrogation of the cable using conventional optical time-domain reflectometry (OTDR) instruments allows water ingress points to be identified and located with a spatial resolution of 50 cm. The system has been tested in a simulated tendon duct grouting experiment as a means of mapping the extent of fill along the duct during the grouting process. Voided regions were detected and identified to within 50 cm. A series of salt solutions has been used to determine the sensor behaviour over a range of water potentials. These experiments predict that measurements of soil moisture content can be made over the range 0 to – 1500 kPa. Preliminary data on soil measurements have shown that the sensor can detect water pressure changes with a resolution of 45 kPa. Applications for the sensor include quality assurance of grouting procedures, verification of waterproofing barriers and soil moisture content determination (for load-bearing calculations).